| TEST STAND CAPABILITY & PRICING |
|
|
|
|
The test stand has five flow meters plumbed in series. All of the flow meters share the same load control valve. The flow meters are selected through the use of ball valves. The three smallest flow meters have quick couplers plumbed in between the ball valve and flow meter so you can check case drain while the main flow is being checked. There are extra returns to tank so that multiple stage pumps may be run if required. The stand is equipped with open and closed loop circuits. Closed loop motors, such as hydrostat motor, are tested (as if they were a pump) by flowing oil through a rectifier circuit and loading the outlet side.
Test stand capability through load control circuit is based on 100-hp electric motor and 90% pump efficiency.
NO LOAD----100 GPM
2500 PSI-----60 GPM
3800 PSI-----40 GPM
5000 PSI-----30 GPM
SPECIFICATIONS FOR HYDRAULIC TEST STAND
- Flow meters- 100gpm, 75gpm, 30gpm, 10gpm, and 5gpm
- Ball valves for flow meter selection.
- Panel mount hydraulic load control valve.
- 3-hp electric motor with charge pump for hydrostat motor test.
- Panel mount auxiliary charge pressure control.
- 4 inch face panel mounted gauges, two 0-600, one 0-3000, and one 0-6000psi
- Air to oil heat exchanger.
- Three 2-1/2" suction quick disconnect sockets. Six 2-1/2" suction quick disconnect plugs.
- 120 gallon JIC reservoir
- Filter in open and closed loop circuits and filter on return to tank
- 100 -hp, "C" face open drip proof electric motor.
- Three drive couplers and "C" face adaptors provided. Sized per customer specifications.
- Detailed circuit drawing and owners manual will be provided.
Base price with standard across the line starter with reverse- $66,875
Time of delivery from date of deposit is 17 to 19 weeks.
Options
- Soft start with reverse add- $2,000
- Variable frequency drive with reverse add- $4,500
- 100-hp double end shaft, double "C" face open drip proof electric motor. 30gpm 5000psi pressure compensated auxiliary hydraulic pump. This option is required for dynamic brake motor test option or the valve test option. $11,125
- Dynamic braking system for hydraulic motor test from 175-20,000 lb/in torque add - $8,125
- Sub plate and adaptors for valve test from DG3, DG5, and DG8 add- $1,500
- Additional drive couplings and "C" face adaptors available. Price will vary with size and model.
OPTION FOR DYNAMIC BRAKE HYDRAULIC MOTOR TEST
- Panel mount auxiliary pump pressure control
- 100-hp double end shaft, double "C" face open drip proof electric motor
- 30gpm 5000-psi pressure compensated auxiliary hydraulic pump w/ mounting hardware- $11,125
Dynamic braking system assembly capable of motor torque test from 175-20,000 lb/in - Panel mounted torque gauge- $8,125
OPTION PACKAGE FOR HIGH PRESSURE VALVE TEST
- Panel auxiliary pump pressure control valve
- 100-hp double end shaft, double "C" face open drip proof electric motor
- 30-gpm 5000-psi pressure compensated auxiliary hydraulic pump w/ mounting hardware- $11,125
Sub plate for Vickers DG8 and adaptor plates for DG3 and DG5 valves- $1,500
|
|
|
|